buying guides

SCSI Connector and Termination Buying Matrix

Match DB25, IDC 50, Centronics 50, and SCA-80 to the right SCSI cable or backplane, then choose a terminator that fits your bus and signaling.

Illustrated title card for the guide: SCSI Connector and Termination Buying Matrix

If the DB25 port on your SCSI host and the Centronics 50 port on your peripheral are both female, buy an external male-to-male DB25-to-Centronics 50 SCSI cable. For an internal IDC 50 drive, buy a 50-pin ribbon cable. For Wide SCA-80, start with a compatible backplane. Plan termination at both physical ends of the bus before buying a separate terminator. IOI cable catalog · Sun Netra 440 overview · IOI termination FAQ

SCSI connector buying matrix

What you haveHow to identify itWhat to buy
DB25 SCSIExternal D-sub with 25 contacts. Confirm that the port is labeled or documented as SCSI.Match DB25 at the host and the exact connector at the peripheral. IOI lists the CB-034 with a male DB25 end and a male CN50 end. DataPro DB25 specs · IOI cable catalog
IDC 50Internal 50-pin ribbon connector.An internal Narrow SCSI ribbon cable with matching IDC 50 ends. If a single-ended setup needs a separate terminator, look for a compatible 50-pin active terminator that mounts on the ribbon. IOI cable catalog · DataPro internal terminator
Centronics 50 (CN50)External 50-pin connector. Check the device documentation for Centronics 50. PDE lists Centronic 50 and High Density 50 separately, so confirm the connector designation before ordering.Match CN50 at the peripheral. IOI lists a CN50-to-CN50 cable for matching ports. If the far end needs a separate CN50 terminator, look for one that matches the bus. IOI cable catalog · PDE terminator catalog
Wide SCA-80An 80-pin drive connector. On the Sun Netra 440, it carries power and signals through a single backplane connection.A compatible SCA backplane. Sun Netra 440 overview

Choose the terminator before ordering

  1. Trace both physical ends. If the host adapter is at one end, check whether it provides termination there. At the far end, enable termination on the last device if it provides it, or place a terminator at the bus end. Disable termination on devices between the ends. IOI termination FAQ · IBM AHA-2940W guide
  2. Match the bus width. When 8-bit Narrow and 16-bit Wide chains meet at the adapter, trace where each byte ends. For example, IBM specifies Low Off / High On at the AHA-2940W adapter when only its internal 50-pin and external 68-pin ports are in use. Terminate the last device on each chain without an automatically terminated hot-swap backplane. Leave termination off on devices connected to such a backplane. IOI termination FAQ · IBM AHA-2940W guide
  3. Match the signaling. For a single-ended (SE) setup, IOI allows passive termination on non-Ultra buses and calls for active negation on single-ended Ultra SCSI. High-voltage differential (HVD) and SE are electrically incompatible. IOI termination FAQ · IBM SCSI signaling guide

Worked example for DB25 to Centronics 50

Suppose a single-ended SCSI host on a non-Ultra bus has a female DB25 port and provides termination at its end. The single external peripheral has female CN50 ports and needs an external terminator. Buy a DB25 male to CN50 male SCSI cable. Connect the DB25 end to the host and the CN50 end to the peripheral. Choose a terminator with a matching CN50 connector and documented compatibility with the single-ended bus. IOI allows passive termination on this non-Ultra bus. Place the terminator at the far end of the bus. IOI cable catalog · PDE terminator catalog · IOI termination FAQ

Check that the cable listing says SCSI and Centronics 50. A parallel printer cable can also have a DB25 end. For example, DataPro’s IEEE 1284 printer cable pairs DB25 with Centronics 36. IOI cable catalog · DataPro printer cable specs

Choose a backplane or a cabled Wide drive

Match the drive to the system’s connection: a compatible backplane for an SCA-80 drive or a matching drive interface for a 68-pin SCSI cable. Sun Netra 440 overview · IBM AHA-2940W guide

For a cabled LVD (low-voltage differential) setup, check whether the cable includes an LVD terminator. If the far end lacks termination, add a terminator that matches the bus. For a backplane setup, check the system documentation for how that end is terminated. IOI cable catalog · IOI termination FAQ · IBM AHA-2940W guide

Evidence and limits. The examples are based on manufacturer documentation checked on November 26, 2026, including IBM’s AHA-2940W guide and Sun’s Netra 440 overview, document 817-3881-12. The configurations shown were not tested for this article.

Sources

  1. IOI SCSI cable catalog
  2. DataPro DB25 connector specifications
  3. DataPro internal 50-pin active terminator specifications
  4. PDE Technology SCSI terminator catalog
  5. DataPro IEEE 1284 parallel printer cable
  6. IBM SCSI general information
  7. IOI SCSI termination FAQ
  8. IBM guide to Adaptec AHA-2940 and AHA-2940W adapters
  9. Sun Netra 440 Server Product Overview, 817-3881-12